Parr-instrument Series 4570 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Parr-instrument Series 4570. Parr Instrument Series 4570 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Operating Instruction Manual

397M4570HP/HT Pressure ReactorsOperating Instruction Manual

Strona 2 - TABLE OF CONTENTS

- 10 - 4570 HP/HT Pressure Reactors Parr Instrument Company IDENTIFY THE VALVES Gas Inlet Valve The gas inlet valve is easily identified when the

Strona 3 - PREFACE

- 11 - 4570 HP/HT Pressure Reactors Parr Instrument Company OTHER VESSEL HEAD FITTINGS Safety Rupture Disc There is a safety rupture disc attache

Strona 4 - PREFACE (Continued)

- 12 - 4570 HP/HT Pressure Reactors Parr Instrument Company HOW TO USE THE VESSEL Fixed Head Vessels: First, lower the heater and push it to

Strona 5

- 13 - 4570 HP/HT Pressure Reactors Parr Instrument Company HOW TO USE THE VESSEL (Continued) Pressurizing the Vessel Check all valves carefully b

Strona 6 - INSTALLATION

- 14 - 4570 HP/HT Pressure Reactors Parr Instrument Company ACCESSORIES Internal Cooling Coil A serpentine cooling coil is mounted to the under

Strona 7 - ASSEMBLE THE REACTOR

- 15 - 4570 HP/HT Pressure Reactors Parr Instrument Company ACCESSORIES (continued) Air Motor Variable stirring speeds from 300 to 2000 rpm with

Strona 8

- 16 - 4570 HP/HT Pressure Reactors Parr Instrument Company The flow control valves have been preset for optimum performance. Both the speed and lif

Strona 9

- 17 - 4570 HP/HT Pressure Reactors Parr Instrument Company EXPLOSION PROOF OPERATION If the local safety code requires that equipment installed

Strona 10 - IDENTIFY THE VALVES

- 18 - 4570 HP/HT Pressure Reactors Parr Instrument Company PERIODIC PRESSURE TESTS Each cylinder used in a Parr stirred reactor is tested under hy

Strona 11 - OTHER VESSEL HEAD FITTINGS

- 19 - 4570 HP/HT Pressure Reactors Parr Instrument Company GENERAL MAINTENANCE NOTES 1. Periodically inspect all electrical wiring and pressure co

Strona 12 - HOW TO USE THE VESSEL

- 2 - 4570 HP/HT Pressure Reactors Parr Instrument Company TABLE OF CONTENTS Related Instructions...2 Customer Service...

Strona 13

- 20 - 4570 HP/HT Pressure Reactors Parr Instrument Company REACTION VESSEL PARTS LIST Consult the itemized list for your reactor, provided along

Strona 14 - ACCESSORIES

- 21 - 4570 HP/HT Pressure Reactors Parr Instrument Company Part No. Description Code Stirrer Shafts* - Standard one piece A1120HC (LD) / A1180HC

Strona 15 - ACCESSORIES (continued)

- 22 - 4570 HP/HT Pressure Reactors Parr Instrument Company Part No. Description Code External Fittings Gage Port 208HC15 Gage adapter

Strona 16

- 23 - 4570 HP/HT Pressure Reactors Parr Instrument Company Model 4571 1000 mL Removable Reactor

Strona 17 - OPERATION

- 24 - 4570 HP/HT Pressure Reactors Parr Instrument Company Overarm Parts List Part No. Description Motor A388E6 Air Motor A388EES Motor

Strona 18 - PERIODIC PRESSURE TESTS

- 25 - 4570 HP/HT Pressure Reactors Parr Instrument Company Overarm Assembly

Strona 19 - GENERAL MAINTENANCE NOTES

- 26 - 4570 HP/HT Pressure Reactors Parr Instrument Company Vessel Heater Stand & Parts List For Removable Vessels Part No. Description

Strona 20 - REACTION VESSEL PARTS LIST

- 27 - 4570 HP/HT Pressure Reactors Parr Instrument Company 4570 Vessel Stand2350HC9 Motor encasement 2565HC Lower back plate 2566HC Upper back plat

Strona 22

- 3 - 4570 HP/HT Pressure Reactors Parr Instrument Company PREFACE Scope These instructions describe the installation, operation and maintenance

Strona 23

- 4 - 4570 HP/HT Pressure Reactors Parr Instrument Company PREFACE (Continued) Explanation of Symbols II On position, full power heater switch I

Strona 24 - Overarm Parts List

- 5 - 4570 HP/HT Pressure Reactors Parr Instrument Company PREFACE (Continued) Intended Usage This system has been designed for use as a high pre

Strona 25 - Overarm Assembly

- 6 - 4570 HP/HT Pressure Reactors Parr Instrument Company INSTALLATION Pressure and Temperature Limits The working pressure and temperature at w

Strona 26 - Parr Instrument Company

- 7 - 4570 HP/HT Pressure Reactors Parr Instrument Company ASSEMBLE THE REACTOR These reactors require at least 10 sq. ft. of workspace in a well-ve

Strona 27 - 4570 Vessel Stand

- 8 - 4570 HP/HT Pressure Reactors Parr Instrument Company ASSEMBLE THE REACTOR (Continued) The pneumatic package includes a pressure regulator wit

Strona 28 - Revision 03/14/13

- 9 - 4570 HP/HT Pressure Reactors Parr Instrument Company ASSEMBLE THE REACTOR (Continued) 6. Connect the thermocouple and extension wire to both

Komentarze do niniejszej Instrukcji